top of page
0401 177 274
Perth, Western Australia
Battery Rack Storage - Victron Smart LFP / NG
Battery, BMS & Monitoring
Redundant System Options
12.8V, 25.6V & 51.2V
ASR designed energy storage racks are a perfect for high scale battery solutions that are capable of paralleled redundant back up systems.
​
The Lynx Smart BMS can support up to 20 Smart LFP batteries providing up to 84kWh in 12.8V and up to 102kWh in 25.6V & 51.2V systems.
​
The Lynx Smart BMS NG can support up to 50 Lithium NG batteries providing up to 192kWh in 12.8V and up to 384kWh in 25.6 & 51.2V systems​
​
A parallel redundant battery bank can be created by combining multiple Lynx Smart BMS and Lynx Smart BMS NG units with their associated battery banks. This innovative feature significantly enhances lithium battery systems by multiplying the maximum energy storage capacity and supporting higher currents. More importantly, it introduces redundancy, ensuring that the system remains operational even if one battery bank fails. This redundancy is crucial for maintaining a continuous power supply and operation.
​
​System Specifications
-
System Specifications Built-in 500A (600A for 5 minutes) or 1000A Contactor (1200A for 5 mins)
-
Main switch or Emergency on/off
-
Pre-charge circuit
-
Monitoring & Control via Cerbo GX / Ekrano
-
DVCC as well as ATC/ATD contacts
-
Programmable relay
-
AUX terminal (power to Cerbo GX / Ekrano)
-
VE.Can / NMEA2000 communication
-
Lynx Distributor & fused monitoring
-
Parallel & redundancy compatible


Key Features
-
Increased capacity and redundancy: By paralleling battery banks, the system can handle higher currents and remain operational even if one battery bank fails.
-
Extended compatibility: In these configurations, Lynx Smart BMS analogue units can be mixed with Lynx Smart BMS NG units, allowing for systems that combine battery banks with Lithium Smart and Lithium NG batteries. However, only Lynx Smart BMS units with the same current rating may be used in parallel (e.g., 500A + 500A or 1000A + 1000A, but not 500A + 1000A).
-
Automatic error handling: If a battery bank encounters an error, it will disconnect while the remaining battery banks continue to operate. This ensures a continuous power supply and reduces the risk of system shutdown.
-
Enhanced monitoring: The system provides a detailed view of all connected and disconnected battery banks in the GX device list, enabling comprehensive monitoring and diagnostics.
-
Seamless reconnection: When a disconnected BMS is ready to connect, it will safely reconnect the battery bank without causing significant current surges.
-
Automatic integration of new battery banks: No configuration required.
​



Ekrano System Monitoring
Lynx Smart BMS NG
Smart LFP NG 25.6V 200Ah


BMS + Battery
System 1
BMS + Battery
System 2
bottom of page